50XKIT-DMT-HEAT
In stock
Brand and model |
DMTech – DMT-D900-T-A1R-V2 |
---|---|
Voltage DC |
9-30VDC |
pa_consumption-standby-mode- |
50μA |
Consumption alarm (Max.) |
20mA |
Initiation time (Max.) |
60 Seconds |
Flash frequency |
16 Secs. |
Permissible cable section |
0.4~2.0 mm2 |
Certification |
EN54 part 5 |
Brand |
DMTECH |
Permitted cable |
0.4~2.0mm2 |
Compatibility |
DMTECH V2 and DMT-B9000F detectors |
50XKIT-DMT-OPTICAL
In stock
Brand and model |
DMTECH – D9000-SR-V2 |
---|---|
Voltage DC |
9-30VDC |
pa_consumption-standby-mode- |
130μA |
Consumption alarm (Max.) |
20mA |
Initiation time (Max.) |
60 Seconds |
Flash frequency |
16 Secs. |
Degree of protection |
IP40 |
Permissible cable section |
0.4~2.0 mm2 |
Certification |
EN54 part 7 |
Brand |
DMTECH |
Permitted cable |
0.4~2.0mm2 |
Compatibility |
DMTECH V2 and DMT-B9000F detectors |
ADV-20-V200
In stock
Brand |
Advanced |
---|---|
Series |
VEGA |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 4 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
58 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5, EN 54-7 and EN54-17 |
ADV-AXIS-HT
In stock
Brand |
Advanced |
---|---|
Series |
AXIS |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 2 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
58 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5 y EN54-17 |
ADV-AXIS-HTX
In stock
Brand |
Advanced |
---|---|
Series |
AXIS |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 2 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
58 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5 y EN54-17 |
ADV-AXIS-OH
In stock
Brand |
Advanced |
---|---|
Series |
AXIS |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 4 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
58 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5, EN 54-7 and EN54-17 |
ADV-AXIS-OHX
In stock
Brand |
Advanced |
---|---|
Series |
AXIS |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 4 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
58 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5, EN 54-7 and EN54-17 |
ADV-AXIS-OP
In stock
Brand |
Advanced |
---|---|
Series |
AXIS |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 4 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
49 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-7 and EN 54-17 |
ADV-AXIS-OPX
In stock
Brand |
Advanced |
---|---|
Series |
AXIS |
Voltage DC |
Nominal Relay Switching current 24V (18~40V) |
Consumption alarm (Max.) |
20mA@24VDC |
Alarm thresholds |
Up to 4 selectable alarm thresholds |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
49 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-7 and EN 54-17 |
ADV-AXIS-RHT
In stock
Brand |
Advanced |
---|---|
Communication distance |
200m in open field |
Operating frequency |
868.15MHz – 869.85MHz |
Type of modulation |
FSK |
Frequency channels |
7 |
Radiation power |
5dBm (3mW) |
Transmission frequency |
60s default |
Power |
Primary Battery: CR123A Secondary Battery: CR123A8 total life years |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
70 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5 and EN 54-25 |
ADV-AXIS-ROH
In stock
Brand |
Advanced |
---|---|
Communication distance |
200m in open field |
Operating frequency |
868.15MHz – 869.85MHz |
Type of modulation |
FSK |
Frequency channels |
7 |
Radiation power |
5dBm (3mW) |
Transmission frequency |
60s default |
Power |
Primary Battery: CR123A Secondary Battery: CR123A8 total life years |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
70 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5, EN54-7 and EN 54-25 |
ADV-AXIS-ROP
In stock
Brand |
Advanced |
---|---|
Communication distance |
200m in open field |
Operating frequency |
868.15MHz – 869.85MHz |
Type of modulation |
FSK |
Frequency channels |
7 |
Radiation power |
5dBm (3mW) |
Transmission frequency |
60s default |
Power |
Primary Battery: CR123A Secondary Battery: CR123A8 total life years |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
70 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-7 and EN 54-25 |
ADV-AXIS-THT
In stock
Brand |
Advanced |
---|---|
Protocol |
TAURUS |
Communication distance |
1000m in open field |
Operating frequency |
868.15MHz – 869.85MHz |
Type of modulation |
FSK |
Frequency channels |
66 |
Radiation power |
14 dBm (25 mW) |
Transmission frequency |
60s default |
Power |
Primary Battery: CR123A Secondary Battery: CR123A10 total life years |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
70 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5 and EN 54-25 |
ADV-AXIS-TOH
In stock
Brand |
Advanced |
---|---|
Protocol |
TAURUS |
Communication distance |
1000m in open field |
Operating frequency |
868.15MHz – 869.85MHz |
Type of modulation |
FSK |
Frequency channels |
66 |
Radiation power |
14 dBm (25 mW) |
Transmission frequency |
60s default |
Power |
Primary Battery: CR123A Secondary Battery: CR123A10 total life years |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
70 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-5, EN54-7 and EN 54-25 |
ADV-AXIS-TOP
In stock
Brand |
Advanced |
---|---|
Protocol |
TAURUS |
Communication distance |
1000m in open field |
Operating frequency |
868.15MHz – 869.85MHz |
Type of modulation |
FSK |
Frequency channels |
66 |
Radiation power |
14 dBm (25 mW) |
Transmission frequency |
60s default |
Power |
Primary Battery: CR123A Secondary Battery: CR123A10 total life years |
Operating temperature range |
-10ºC ~ +55ºC |
Humidity (non condensing) |
95% RH |
Dimensions |
70 x 100 mm (H x D) / 130g |
IP protection |
IP40 |
Certification |
EN54-7 and EN 54-25 |
AJ-CURTAINOUTDOOR-W
Out of stock
Brand |
Ajax |
---|---|
Technology |
Dual curtain-type PIR with K-band microwave (24 GHz) |
Detection range |
8~12 m / 8º H / 85º V / Installation 2.4 m |
Frequency |
868 MHz Jeweller |
Transmission distance |
⤠1700 m in open space |
Anti-masking |
Available |
Sensitivity |
Adjustable. 3 levels (high, medium, low) |
Detection range configuration |
In the device (Far: to 12 m / Near: to 8 m / Pet: anti-pet up to 12 m) |
Tamper-resistant opening |
Available |
LEDs indication |
Alarm, tamper, signal |
Anti-pet |
Pets up to 100 cm (height installation): 1 m) |
Compatibility |
Compatible with Ajax Hub 2 (2G and 4G), Hub 2 Plus, Hub Hybrid (2G and 4G) and ReX 2 |
Power |
2 batteries CR123A 3.0 V (approximate life time 3 years) |
Temp. operation |
-25 ºC ~ 60 ºC |
Operating Humidity |
95% |
Degree of protection |
IP55 |
Brackets |
Includes SmartBracket, angle bracket and cover |
Dimensions with cover |
155 (H) x 77 (W) x 85 (D) mm |
Dimensions without cover |
141 (H) x 50 (W) x 72 (D) mm |
Colour |
White |
EL2800
In stock
Brand |
Electronics Line |
---|---|
Technology |
Pet-proof dual PIR |
Detection range |
Range 2~12 m / coverage 90º for installation height 0.8~1.2m |
Frequency |
868 MHz |
Pet immunity |
⤠45 Kg |
Masking |
Does not have |
Sensitivity |
Adjustable, Low or High |
LEDs indication |
Alarm, signal, battery |
Battery |
2 x 3V CR123A |
Temp. operation |
-10º C ~ 55º C |
Degree of protection |
Suitable for exterior IP65 |
JBE-2106
In stock
Brand |
Jade Bird |
---|---|
Operating voltage |
16-30 VDC |
Connection |
JBE communication bus 2 wires, no polarity |
Wired |
Twisted pair without mesh 0.5 – 2.5 mm² |
Consumption in idle mode |
â¤0.3mA @24 V |
Consumption in alarm mode |
â¤1 mA @24 V (up to 8 mA of remote indicator) |
Temp. of work |
-10 to +60ºC |
Temp. storage |
-20 to +60ºC |
Humidity |
⤠95% HR (40 ±2ºC) (no condensation) |
Address |
Through the JBE-AT1 addressing tool |
Address range |
1-200 |
Coverage |
20 to 30 m2 |
LED indicator |
Rest: Blinking with loop pollingAlarm: Fixed ignition |
Dimensions (ÃxH) |
100 mm à 41 mm |
Weight |
0,1 kg |
Protection Grade |
IP40 |
Supported bases |
JBE-2160 for installation without indicator remoto, JBE-2165 for installation with remote indicator |
Remote indicator |
LED with or without series resistor (R <4Kâ¦) |
Certificado |
EN 54-5:2017+A1:2018 |