Showing 1–36 of 65 results
Filter by price
Intrusion
2XIBS-SH-50-8TD
In stock
Detection range |
50m outdoor |
---|---|
Number of beams |
8 |
Work frequency |
433MHz FSK+FHSS |
Wireless range |
Up to 1000m |
Maximum detections per day |
â¤200 times |
Address |
Dual (Several barriers can be installed in series IBS-SH-50-8TD) |
Operating temperature |
-30ºC ~ +70ºC |
Degree of protection |
IP65 |
Internal battery |
3.3V / 6000mAh LiFePO4 |
Solar panel output |
2W |
LED light power consumption |
<1W |
Dimensions |
140 (h) x 15 (Ã) cm |
AB-60
In stock
Detection range |
180m indoor / 60m outdoor |
---|---|
Number of beams |
2 |
Detection method |
Interruption of the 2 beams at once |
Interruption time |
50ms, 100ms, 300ms, 700ms (available) |
Frequency channels |
4 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 1A), Tamper NC |
Alignment angle |
Horizontal 180°(±90°), Vertical 20°(±10°) |
Adjustment method |
Over LCD Display between 0-99 |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~24 VDC/VAC, 75 mA max. |
Dimensions |
211.5 (H) x 79.9 (W) x 74.7 (D) mm |
ABE-150
In stock
Detection range |
450m indoor / 180m outdoor |
---|---|
Number of beams |
3 |
Detection method |
Interruption of the 3 beams at once |
Interruption time |
50ms, 100ms, 300ms, 700ms (available) |
Frequency channels |
4 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 1A), Tamper NC |
Alignment angle |
Horizontal 180°(±90°), Vertical 20°(±10°) |
Adjustment method |
Over LCD Display between 0-99 |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~24 VDC/VAC, 200 mA max. |
Dimensions |
291 (H) x 92 (W) x 90 (D) mm |
ABH-100W
Out of stock
Use |
Infrared barrier detector |
---|---|
Detection range |
300m indoor / 100m outdoor |
Number of beams |
4 |
Detection method |
Interruption of the 4 beams at once or only 2 (up o down) |
Interruption time |
50ms, 100ms, 300ms, 700ms (available) |
Frequency channels |
4 different channels over DIP Switch |
Outputs |
Alarm output NO/NC , tamper output NC, low battery output NC |
Compatibility |
Compatible with Ajax Transmitter module or Ajax DoorProtect/DoorProtect Plus external contact |
Alignment angle |
Horizontal 180°(±90°), Vertical 20°(±10°) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
Batteries ER34615H, includes 2 batteries (one for each barrier) |
Autonomy |
3 years with one battery and 6 years with two batteries each barriers |
Dimensions |
402 (H) x 110(An) x 166 (D) mm |
Installation |
Exterior or interior, on wall or pole |
ABH-150L
In stock
Detection range |
450m indoor / 150m outdoor |
---|---|
Number of beams |
4 |
Detection method |
Interruption of the 4 beams at once or only 2 (up o down) |
Interruption time |
50ms, 100ms, 300ms, 700ms (available) |
Frequency channels |
4 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A), Tamper NC |
Alignment angle |
Horizontal 180°(±90°), Vertical 20°(±10°) |
Adjustment method |
Over LCD Display between 0-99 |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~24 VDC/VAC, 90 mA max. |
Dimensions |
291 (H) x 92 (W) x 90 (D) mm |
ABH-200W
In stock
Use |
Infrared barrier detector |
---|---|
Detection range |
600m indoor / 200m outdoor |
Number of beams |
4 |
Detection method |
Interruption of the 4 beams at once or only 2 (up o down) |
Interruption time |
50ms, 100ms, 300ms, 700ms (available) |
Frequency channels |
4 different channels over DIP Switch |
Outputs |
Alarm output NO/NC , tamper output NC, low battery output NC |
Compatibility |
Compatible with Ajax Transmitter module or Ajax DoorProtect/DoorProtect Plus external contact |
Alignment angle |
Horizontal 180°(±90°), Vertical 20°(±10°) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
Batteries ER34615H, includes 2 batteries (one for each barrier) |
Autonomy |
3 years with one battery and 6 years with two batteries each barrier |
Dimensions |
402 (H) x 110(An) x 166 (D) mm |
Installation |
Exterior or interior, on wall or pole |
ABH-250L
In stock
Detection range |
750m indoor / 250m outdoor |
---|---|
Number of beams |
4 |
Detection method |
Interruption of the 4 beams at once or only 2 (up o down) |
Interruption time |
50ms, 100ms, 300ms, 700ms (available) |
Frequency channels |
4 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A), Tamper NC |
Alignment angle |
Horizontal 180°(±90°), Vertical 20°(±10°) |
Adjustment method |
Over LCD Display between 0-99 |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~24 VDC/VAC, 90 mA max. |
Dimensions |
291 (H) x 92 (W) x 90 (D) mm |
ABI100-1086
In stock
Detection range |
100m outdoor |
---|---|
Number of beams |
6 |
Detection method |
Interruption of 2 continuous beams at a time |
Sensitivity |
Adjustable between L, M H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
9~30 VDC, 50~120 mA |
Dimensions |
108(H) x 4(W) x 7(D)cm |
ABI100-1408
In stock
Detection range |
100m outdoor |
---|---|
Number of beams |
8 |
Detection method |
Interruption of 2 continuous beams at a time |
Sensitivity |
Adjustable between L, M and H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
9~30 VDC, 50~120 mA |
Dimensions |
140(H) x 4(W) x 7(D)cm |
ABI30-1408
In stock
Detection range |
30m outdoor |
---|---|
Number of beams |
8 |
Detection method |
Interruption of 2 continuous beams at a time |
Sensitivity |
Adjustable between L, M H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
9~30 VDC, 50~120 mA |
Dimensions |
140(H) x 4(W) x 7(D)cm |
ABI30-764
Out of stock
Detection range |
30m outdoor |
---|---|
Number of beams |
4 |
Detection method |
Interruption of 2 continuous beams at a time |
Sensitivity |
Adjustable between L, M H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
9~30 VDC, 50~120 mA |
Dimensions |
76(H) x 4(W) x 7(D)cm |
ABL-J5003
Out of stock
Detection range |
500m outdoor |
---|---|
Number of beams |
3 |
Detection method |
Configurable: alarm by cutting one beam, two beams or all beams at once |
Sensitivity |
Adjustable (50/100/300/700 ms) |
Frequency channels |
Each beam works at its own frequency |
Alarm outputs |
1 relay NO/NC (max. AC125V/0.5A, DC24V/1A) |
Alignment angle |
H: ±15º / V: ±15º |
Adjustment method |
Through LED and alignment tool (ABL-JYD) |
Operating temperature |
-25ºC ~ +70ºC |
Degree of protection |
IP67 |
Power |
12~24 VDC/VAC, 150 mA max. |
MTBF |
120.000 hours |
Dimensions |
66.7 (H) x 39 (W) x 25.3 (D) mm |
ABL100-1508A
In stock
Detection range |
100 m exterior |
---|---|
Number of beams |
8 |
Detection method |
Interruption of 2 continuous beams at a time |
Communication |
One address per tower: sender or receiver |
Sensitivity |
Adjustable between L, M, H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
LED light |
E27 230VAC (included) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~18 VDC, 90 mA max. |
Dimensions |
150 cm height |
ABL100-18510A
In stock
Detection range |
100 m exterior |
---|---|
Number of beams |
10 |
Detection method |
Interruption of 2 continuous beams at a time |
Communication |
One address per tower: sender or receiver |
Sensitivity |
Adjustable between L, M, H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
LED light |
E27 230VAC (included) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~18 VDC, 90 mA max. |
Dimensions |
185 cm height |
ABL100-18510B
In stock
Detection range |
100 m exterior |
---|---|
Number of beams |
10 |
Detection method |
Interruption of 2 continuous beams at a time |
Communication |
Two directions per tower: transmitter and receiver |
Sensitivity |
Adjustable between L, M, H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
LED light |
E27 230VAC (included) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~18 VDC, 90 mA max. |
Dimensions |
185 cm height |
ABL30-18510A
In stock
Detection range |
30 m exterior |
---|---|
Number of beams |
10 |
Detection method |
Interruption of 2 continuous beams at a time |
Communication |
One address per tower: sender or receiver |
Sensitivity |
Adjustable between L, M, H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
LED light |
E27 230VAC (included) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~18 VDC, 90 mA max. |
Dimensions |
185 cm height |
ABL30-18510B
In stock
Detection range |
30 m exterior |
---|---|
Number of beams |
10 |
Detection method |
Interruption of 2 continuous beams at a time |
Communication |
Two directions per tower: transmitter and receiver |
Sensitivity |
Adjustable between L, M, H |
Frequency channels |
2 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 30VDC/VAC, 0.5A) |
Alignment angle |
Horizontal 180°(±90°) |
Adjustment method |
Over LED and buzzer |
LED light |
E27 230VAC (included) |
Operating temperature |
-25ºC ~ +55ºC |
Degree of protection |
IP65 |
Power |
12~18 VDC, 90 mA max. |
Dimensions |
185 cm height |
ABO-20F
In stock
Detection range |
20m indoor / 10 m outdoor |
---|---|
Number of beams |
1 |
Detection method |
Infrared beam interruption |
Frequency channels |
4 different channels over DIP Switch |
Alarm outputs |
1 relay NO/NC (max. 36VDC/VAC, 1A) |
Adjustment method |
Over LED |
Operating temperature |
-25ºC ~ +55ºC |
Power |
9~16 VDC/VAC, 20 mA max. |
Dimensions |
69.5 (H) x 26.4 (W) x 22.5 (D) mm |
ABO-20L
In stock
Detection range |
20m indoor / 10 m outdoor |
---|---|
Number of beams |
1 |
Detection method |
Infrared beam interruption |
Frequency channels |
1 channel |
Alarm outputs |
1 relay NO/NC (max. 36VDC/VAC, 1A) |
Adjustment method |
Over LED |
Operating temperature |
-25ºC ~ +55ºC |
Power |
12~24 VDC/VAC, 30 mA max. |
Dimensions |
75.3 (H) x 49.2 (W) x 29.6 (D) mm |
DT-400-AJ
In stock
Brand |
Defendertech |
---|---|
Ajax Relays |
2 units already installed (for arming and executing) |
Fog Dispensed in |
415 m3 |
Fog Dispensing Time |
1-60 seconds |
Forced Break Time |
1-60 minutes |
Total Despensing Time |
4.5 minutes |
Total Quantity Dispensed |
1870 m3 |
Tank Capacity |
0.5 L |
Heating Time (100%) |
20-30 minutes |
Reaction Time |
200ms |
Burner autonomy without mains power 1 |
60 seconds |
Inputs |
1 Arm Control / 1 Shot Control |
Outputs |
Failure, Liquid and [email protected] |
Power |
AC 220 V |
Nominal power consumed when armed |
600 W |
Battery |
2x 12V/1.3Ah (not included) |
Dimensions |
380 (H) x 380 (W) x 145 (D) mm |
Weight |
10 kg with a full tank |
DT-800-AJ
In stock
Brand |
Defendertech |
---|---|
Ajax Relays |
2 units already installed (for arming and executing) |
Fog Dispensed in |
830 m3 |
Fog Dispensing Time |
1-60 seconds |
Forced Break Time |
1-60 minutes |
Total Despensing Time |
6.5 minutes |
Total Quantity Dispensed |
4980 m3 |
Tank Capacity |
1.5 L |
Heating Time (100%) |
10-12 minutes |
Reaction Time |
200ms |
Burner autonomy without mains power 1 |
60 seconds |
Inputs |
1 Arm Control / 1 Shot Control |
Outputs |
Failure, Liquid and [email protected] |
Power |
AC 220 V |
Nominal power consumed when armed |
1750 W |
Battery |
2x 12V/1.3Ah (not included) |
Dimensions |
450 (H) x 450 (W) x 145 (D) mm |
Weight |
14 kg with a full tank |